24
Move about 1 mm
1. Gently move lug out a fraction with a screwdriver to release the backplate.
2. Pull the backplate back slightly to keep lug from clicking back into place.
3. Repeat with each lug until backplate comes loose.
Analogue output board
High
Normal
High Voltage Input
Link both pairs of posts
for voltage outputs
High voltage input selection
To select high voltage inputs, remove the back plate by gently prising
apart the four clips that hold it in place, place the link (on the main
board) as appropriate and reassemble.