• Setup Sequence
Setting Display Description
Å ì
ENT
S/W Version
v1.01
S/W Version 1.01 (Note: this information only applies to
versions 1.00 to 1.09)
Next
Instrument Type
Freq
PMX400/HZX Next
Display and Inputs
Display Intensity
HIbr
LObr
High brightness
Low Brightness
Toggle Accept
Input type
Inp=
LOAC
H AC
LOdC
HIdC
Con
SGL1
SGL2
SGL3
SGL4
Introduces input type
Low level AC signal
High level AC signal
Low level DC signal
High level DC signal
Contact Closure
Special signal - type 1
Special signal - type 2
Special signal - type 3
Special signal - type 4
Next Prev Accept
Input frequency
range
FdP=
.
Decimal point position Shift
Next
Accept
FLO=
300
Input frequency range lower limit
e.g., 300 Hz
-
Dec
-
Inc
Next
Accept
FHI=
1000
Input frequency range upper limit
e.g., 1 kHz
-
Dec
-
Inc
Next
Accept
Damping factor
dF=
2
Introduces the damping factor
Value, e.g., 2
-
Dec
-
Inc
Next
Accept
Display range
dP=
.
Decimal point position Shift
Next
Accept
dLO=
0.0
Display range lower limit
e.g., 0.0
-
Dec
-
Inc
Next
Accept
dHI=
100.0
Display range Upper limit
e.g., 100.0
-
Dec
-
Inc
Next
Accept