Terminal Signal
1
Sense −
Bridge Excitation Voltage
2
Sense +
3
Excitation +
4
Excitation −
6
0 V reference (for calibration only)
Input signal
7
Signal +
8
Signal −
9 Not Used
10 Neutral (−)
Power Supply
11 Live (+)
12 Not Used
13 Output +
Output signal
14 Output −
15,16
Not Used
Case Earthing is via a stud on lower side of case
Note: The power supply is isolated from the rest of the circuit but input and output circuits share a
common negative return.
Sense
+ Sense
+ Excitation
Excitation
+ Signal
Signal
1 2 3 4 7 8
STG
Input connections for STG with remote sensing excitation.
+ Excitation
Excitation
+ Signal
Signal
1 2 3 4 7 8
STG
Input connections for STG with remote sensing disabled.